Partial Discharge (PD)
Electrical discharge that occurs within the insulation of electrical equipment or systems.

Partial discharge (PD) is an electrical discharge that happens locally within the insulation of electrical equipment or systems. It is distinguished by the release of energy in the form of transient electrical pulses, which are typically at a lower voltage than the standard operating voltage. Although a partial discharge may appear to be small, it can have substantial implications such as device failure, insulation degradation, and even catastrophic failures. As a result, partial discharge detection, monitoring, and mitigation are critical in ensuring the dependability and safety of electrical systems.

Partial Discharge Mechanism and Causes: Partial discharge is often caused by high electric field stress within the insulation materials or at interfaces between different insulation materials. Several variables can contribute to it, including:

1. Insulation Defects: Manufacturing flaws in the insulation material, such as vacancies, impurities, or delaminations, can cause localized regions of high electric field stress, resulting in partial discharge.
2. Aging and Deterioration: Insulation materials degrade over time due to reasons such as moisture intrusion, heat cycling, or chemical interactions. These deteriorations can lead to partial discharge circumstances.
3. Impurities and Moisture: The presence of impurities such as dust, moisture, or conductive particles can reduce the insulation’s breakdown voltage and increase the likelihood of partial discharge.
4. Mechanical Stress: Excessive mechanical stress or vibration on electrical components can produce insulation cracks or dislocation, resulting in partial discharge.

Partial Discharge Detection and Monitoring: Detection and monitoring of partial discharge are crucial for identifying possible concerns, assessing the state of insulation, and adopting suitable maintenance measures. For partial discharge testing, several methods are employed, including:

  1. Online monitoring devices: The sensors are fitted into electrical equipment and continuously monitor the presence and intensity of partial discharge. These technologies provide real-time data and enable the early detection of insulation issues.
  2. Detection of Electromagnetic Interference (EMI): PD activity can produce electromagnetic waves that can be detected with EMI sensors. This method is frequently used to detect and locate partial discharge sources in high-voltage equipment such as transformers and cables.
  3. Acoustic Detection: Partial discharge occurrences can produce ultrasonic waves that travel through the insulation material and the surrounding medium. Acoustic sensors can detect these waves, allowing them to determine the presence and intensity of a partial discharge.

The implementation of partial discharge monitoring offers several advantages, including:

  1. Early Fault Detection: Continuous monitoring of partial discharge enables the early detection of insulation defects and degradation, allowing for timely corrective actions and minimizing the risk of equipment failure.
  2. Increased Safety: By identifying potential insulation failures, partial discharge monitoring enhances the safety of personnel and reduces the risk of catastrophic events, such as fires or explosions.
  3. Improved Equipment Reliability: Detecting and mitigating partial discharge helps in maintaining the integrity of electrical systems, extending the lifespan of equipment, and reducing unexpected downtime.
  4. Cost Savings: By preventing equipment failures and optimizing maintenance practices, partial discharge monitoring helps in reducing repair costs, minimizing unplanned outages, and optimizing asset management.

Read more about Partial Discharge here.